plasticizer micro flow measurement

Date:2017-02-01 source:
  plasticizer micro flow measurement  

email: porter@microflowmeter.com  Shanghai JSN Micro Flow MeterCO.,LTD is a manufactory integrating scientific research, production, sales andservice. It is located in the Shanghai Industrial Zone. The company is based onthe people-oriented principle and takes the program as the degree. Competitive,product covers a variety of materials and super micro liquid flow meter,ovalgear flow meter ,mass flow meter.spur gear flow meter,gear pump,gear meteringpump etc instrumentation instrument. Widely applicable to trade settlement andmeasurement in various industries such as petroleum, chemical, environmentalprotection, metallurgy, electric power, transportation, food, medicine,military industry, scientific research, etc.

 plasticizer micro flow measurement

plasticizer micro flow measurement

Withthe development of society, the state pays more and more attention to theprocess automation instrumentation industry. However, the Oval gear flow meter industryhas been in a vacancy and has been monopolized by major foreign brands such asMax, KRACHT, OVAL, etc. , People have long endured the expensive, longdelivery, the sale can not be resolved in time and so on, such as semiconductorchip cutting a set of equipment on the millions, once the instrument problems,loss unimaginable, the slayer saw these phenomena, Resolutely resigned assenior engineer in the position of Siemens, the establishment of ShanghaiJi-sheng Instruments Co., Ltd., with great concentration on research anddevelopment of gear flow meter. We have Oval gear flow meter has been awarded anumber of certificates, it is no exaggeration to say that Qishen production Ovalgear flow meter For example, many customers replace the OVAL LSF40 with ourCX-M5-AL because it costs less than half of the LSF40, but has twice the rangethan it does and has the same accuracy.

Base deep gear wheel flowmeter on the production of all caliberflowmeters, basically have stock inventory, which in itself shows that thecompany"s funds and sales are good, we dare to do inventory. Hee Oval gear flowmeter has two national inventions, In the process of production qualitycontrol, starting from the beginning of the procurement of raw materials, everyproduction and precision machining links careful examination, each of the Ovalgear flow meter factory must be continuous calibration test. Processinstallation ISO9001 quality management system strictly enforced, the producthas the CE, SGS and other EU certification. Our company has "the qualityof Germany, China"s manufacturing" as the slogan to create a world-classoval gear flow, real automation instrumentation industry Benchmarking business.

micro flow measurement

plasticizer micro flow measurement

The Ovalgear flow meter is a volumetric flow meter. The metering chamber is composed ofupper and lower end caps. The shell is formed by an oval gear rotor. The gearrotor meshes with the rotating shaft to convey the fluid. The permanent magnetarranged in the rotor is used for the detection of the rotor rotation. Twosensor holes are placed on the upper end to cover the detection sensor. Asealing ring is installed between the housing and the upper and lower end capsto prevent leakage of the measurement fluid. The base depth flowmeter is madeof a material with high wear resistance so that the flowmeter Can guaranteehigh precision measurement within the long service life.

 plasticizer micro flow measurement

plasticizer micro flow measurement

Technicaldata of Gear type flow meter

Model

K-factor

Minimum  flow

Flow  range

Accuracy

G0.025

0.025ml

0.001L/Min

0.008~2L/Min

0.5%

G0.04

0.04ml

0.004L/Min

0.2~4  L/min

0.5%

G0.1

0.4ml

0.008L/Min

0.01~8L/min

0.5%

G0.2

0.245ml

0.01L/Min

0.16~16  L/min

0.5%

G0.4

0.4ml

0.01L/Min

0.16~16  L/min

0.5%

G1

1.036ml

0.02L/Min

0.4~80  L/min

0.5%


What are the precautions for the gear flow meter?

1) If the medium temperature is too high, or the pressure is too high, please inform us before purchasing, we can customize it for you.

2) When the pipeline is continuously operated and the flowmeter is to be installed in a horizontal pipeline, a bypass pipeline should be installed to facilitate cleaning and overhaul; when the flowmeter is installed on a vertical pipeline, the flowmeter should be installed on the bypass. In the pipeline, to prevent debris from falling into the instrument. When the fluid flows from bottom to top, the vertical tube in the upper part of the flowmeter should be as short as possible to reduce the precipitation of impurities in the upper piping.